"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Conductor Number","Conductor Stranding","Diameter Over Conductor","Insul. Thickness","Diameter Over Insulation","Diameter Over Insulation Shield","Ground","Diameter Over Armor","Jacket Thickness","Approx. OD","Approx. Weight","Max Pull Tension","Min Bending Radius" "","AWG/Kcmil","","","inches","mils","inches","inches","No. x AWG","inch","mils","inches","lbs./MFT","lbs.","inches" TBA,"1","3","19","0.322","320","1.000","1.060","1x4","2.880","75",3.030,"3712","2008","21.2" TBA,"1/0","3","19","0.361","320","1.039","1.099","1x4","2.880","75",3.030,"4009","2534","21.2" "649938","2/0","3","19","0.405","320","1.084","1.144","1x4","3.000","75",3.158,"4619","3194","22.0" TBA,"3/0","3","19","0.456","320","1.134","1.194","1x3","3.220","90",3.400,"5165","4027","23.8" TBA,"4/0","3","19","0.512","320","1.190","1.250","1x3","3.220","90",3.400,"5712","5078","23.8" TBA,"250","3","37","0.558","320","1.244","1.304","1x3","3.540","90",3.720,"6366","6000","26.0" TBA,"350","3","37","0.661","320","1.347","1.407","1x2","3.540","90",3.720,"7608","8400","26.0" "664985","500","3","37","0.766","320","1.452","1.512","1x1","3.850","90",4.028,"9435","12000","28.2" TBA,"750","3","61","0.968","320","1.664","1.724","1x1/0","3.850","90",4.030,"12478","18000","28.2" "All dimensions are nomial and subject to normal manufacturing tolerances" "Table 2 - Electrical and Engineering Data" "Cond. Size","DC Resistance @ 25C","AC Resistance @ 90C","Capacitive Reactance","Inductive Reactance","Zero Sequence Impedance","Positive Sequence Impedance","Shield Short Circuit Current 6 Cycles","Allowable Ampacity In Duct 90/105C","Allowable Ampacity In Air 90/105C" "AWG/Kcmil","ohm/MFT","ohm/MFT","Mohm*MFT","Mohm/MFT","ohm/MFT","ohm/MFT","Amps","Amps","Amps" "1","0.128","0.162","0.059","0.050","0.523 + j0.335","0.162 + j0.05","3315","170/185","185/210" "1/0","0.102","0.128","0.055","0.048","0.485 + j0.322","0.128 + j0.048","3435","195/210","215/240" "2/0","0.081","0.102","0.051","0.046","0.455 + j0.307","0.102 + j0.046","3572","220/235","245/275" "3/0","0.064","0.081","0.047","0.044","0.43 + j0.292","0.081 + j0.044","3730","250/270","285/315" "4/0","0.051","0.065","0.044","0.043","0.408 + j0.276","0.065 + j0.043","3903","285/305","325/360" "250","0.043","0.056","0.041","0.042","0.394 + j0.263","0.056 + j0.042","4071","310/335","360/400" "350","0.031","0.041","0.037","0.039","0.368 + j0.239","0.042 + j0.039","4390","375/400","435/490" "500","0.022","0.030","0.032","0.037","0.345 + j0.213","0.031 + j0.037","4786","450/485","535/600" "750","0.014","0.023","0.028","0.035","0.319 + j0.182","0.024 + j0.035","5372","545/585","670/745"