"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Conductor Number","Conductor Stranding","Diameter Over Conductor","Insul. Thickness","Diameter Over Insulation","Diameter Over Insulation Shield","Jacket Thickness","Approx. OD","Approx. Weight","Max Pull Tension","Min Bending Radius","Conduit Size" "","AWG/Kcmil","","","inches","mils","inches","inches","mils","inches","lbs./MFT","lbs.","inches","inches" TBA,"2","1","7","0.282","115","0.550","0.610","55",0.740,"407","530","8.8","2.5" TBA,"1","1","19","0.322","115","0.590","0.650","55",0.780,"477","669","9.3","2.5" TBA,"1/0","1","19","0.361","115","0.629","0.689","80",0.869,"600","844","10.4","2.5" TBA,"2/0","1","19","0.405","115","0.674","0.734","80",0.940,"785","1064","11.2","3.0" TBA,"3/0","1","19","0.456","115","0.724","0.784","80",0.964,"836","1342","11.5","3.0" TBA,"4/0","1","19","0.512","115","0.780","0.840","80",1.020,"997","1692","12.2","3.0" TBA,"250","1","37","0.558","115","0.834","0.894","80",1.074,"1142","2000","12.8","3.0" TBA,"350","1","37","0.661","115","0.937","0.997","80",1.177,"1498","2800","14.1","3.5" TBA,"500","1","37","0.789","115","1.065","1.125","80",1.305,"2018","4000","15.6","4.0" TBA,"750","1","61","0.968","115","1.254","1.314","80",1.494,"2883","6000","17.9","4.5" TBA,"1000","1","61","1.117","115","1.403","1.463","80",1.643,"3725","8000","19.7","5.0" "All dimensions are nomial and subject to normal manufacturing tolerances" "Table 2 - Electrical and Engineering Data" "Cond. Size","DC Resistance @ 25C","AC Resistance @ 90C","Capacitive Reactance","Inductive Reactance","Zero Sequence Impedance","Positive Sequence Impedance","Shield Short Circuit Current 6 Cycles","Allowable Ampacity In Duct 90/105C","Allowable Ampacity In Air 90/105C" "AWG/Kcmil","ohm/MFT","ohm/MFT","Mohm*MFT","Mohm/MFT","ohm/MFT","ohm/MFT","Amps","Amps","Amps" "2","0.162","0.204","0.034","0.044","0.570 + j0.514","0.204 + j0.045","2849","145/155","190/215" "1","0.128","0.162","0.031","0.042","0.531 + j0.491","0.162 + j0.042","3033","170/180","225/250" "1/0","0.102","0.128","0.028","0.042","0.497 + j0.469","0.128 + j0.042","3212","195/210","260/290" "2/0","0.081","0.102","0.026","0.040","0.473 + j0.447","0.102 + j0.041","3414","220/235","300/330" "3/0","0.064","0.081","0.024","0.039","0.452 + j0.423","0.081 + j0.039","3648","250/270","345/385" "4/0","0.051","0.065","0.021","0.038","0.435 + j0.398","0.065 + j0.038","3906","290/310","400/445" "250","0.043","0.056","0.020","0.037","0.424 + j0.376","0.056 + j0.037","4154","320/345","445/495" "350","0.031","0.041","0.018","0.035","0.404 + j0.338","0.042 + j0.035","4628","385/415","550/615" "500","0.022","0.030","0.015","0.033","0.383 + j0.297","0.031 + j0.033","5216","470/505","695/775" "750","0.014","0.023","0.013","0.032","0.358 + j0.248","0.024 + j0.032","6084","585/630","900/1000" "1000","0.011","0.019","0.011","0.031","0.339 + j0.217","0.020 + j0.031","6769","670/720","1075/1200"