"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Approx. OD","Aluminum Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","inches","lbs./MFT","lbs./MFT" "643576","6","7","1","0.169","85","0.339","24","54" "643580","4","7","1","0.212","85","0.383","39","74" "643583","1","8","1","0.298","105","0.509","78","137" "643587","1/0","10","1","0.336","105","0.546","99","163" "643590","2/0","12","1","0.376","105","0.586","125","195" "643594","3/0","16","1","0.422","105","0.633","158","235" "643597","4/0","19","1","0.474","105","0.685","199","284" "641821","250","22","1","0.520","120","0.760","235","342" "641818","300","21","1","0.569","120","0.810","282","397" "641815","350","35","1","0.615","120","0.856","329","452" "641812","400","35","1","0.659","120","0.899","376","506" "582267","500","34","1","0.735","120","0.978","471","614" "641495","600","37","1","0.812","135","1.083","565","743" "641499","750","61","1","0.908","135","1.178","706","902" "641930","1000","58","1","1.060","135","1.330","942","1166" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "643576","6","1","1.3","157","0.674","0.812","0.051","40","50","55" "643580","4","1","1.5","250","0.424","0.510","0.048","55","65","75" "643583","1","1","2.0","502","0.211","0.254","0.046","85","100","115" "643587","1/0","1","2.1","633","0.168","0.201","0.044","100","120","135" "643590","2/0","1","2.3","798","0.133","0.160","0.043","115","135","150" "643594","3/0","1","2.5","1006","0.105","0.126","0.042","130","155","175" "643597","4/0","1","2.7","1269","0.084","0.100","0.041","150","180","205" "641821","250","1","3.0","1500","0.071","0.086","0.041","170","205","230" "641818","300","1","3.2","1800","0.059","0.071","0.041","195","230","260" "641815","350","1","3.4","2100","0.050","0.062","0.040","210","250","280" "641812","400","1","3.5","2400","0.044","0.054","0.040","225","270","305" "582267","500","1","3.9","3000","0.035","0.044","0.039","260","310","350" "641495","600","1","5.4","3600","0.029","0.037","0.039","285","340","385" "641499","750","1","5.8","4500","0.024","0.031","0.038","320","385","435" "641930","1000","1","6.6","6000","0.018","0.025","0.037","375","445","500" "All dimensions are nominal and subject to normal manufacturing tolerances"