"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Ground","Diameter Over Armor","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","No. x AWG","inches","mils","inches","lbs./MFT","lbs./MFT" "TBA","8","7","3","0.141","45","3 x 14","0.750","50","0.850","186","444" "TBA","6","7","3","0.177","45","3 x 12","0.840","50","0.940","296","589" "647699","4","7","3","0.225","45","1 x 8","0.920","50","1.020","439","718" "677933","2","7","3","0.282","45","1 x 6","1.020","50","1.120","699","1045" "TBA","1/0","19","3","0.361","55","3 x 10","1.350","50","1.450","1067","1679" "672673","2/0","19","3","0.405","55","3 x 10","1.470","50","1.576","1342","1992" "TBA","2/0","19","3","0.405","55","3 x 10","1.480","50","1.580","1324","2001" "586674","3/0","19","3","0.456","55","3 x 8","1.540","60","1.660","1724","2427" "TBA","4/0","19","3","0.512","55","3 x 8","1.670","60","1.790","2105","2963" "TBA","250","37","3","0.558","65","3 x 8","1.845","60","1.965","2465","3458" "TBA","350","37","3","0.661","65","3 x 6","2.200","60","2.320","3435","4623" "TBA","500","37","3","0.789","65","3 x 6","2.430","75","2.580","4878","6371" "TBA","750","61","3","0.968","80","3 x 4","2.880","75","3.030","7268","9190" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps" "TBA","8","3","6.0","396","0.653","0.786","0.052","50","55" "TBA","6","3","6.6","629","0.411","0.495","0.051","65","75" "647699","4","3","7.1","1001","0.258","0.310","0.048","85","95" "677933","2","3","7.8","1592","0.162","0.195","0.045","115","130" "TBA","1/0","3","10.2","2534","0.102","0.122","0.044","150","170" "672673","2/0","3","11.0","3194","0.081","0.097","0.043","175","195" "TBA","2/0","3","11.1","3194","0.081","0.097","0.043","175","195" "586674","3/0","3","11.6","4027","0.064","0.078","0.042","200","225" "TBA","4/0","3","12.5","5078","0.051","0.062","0.041","230","260" "TBA","250","3","13.8","6000","0.043","0.053","0.041","255","290" "TBA","350","3","16.2","8400","0.031","0.039","0.040","310","350" "TBA","500","3","18.1","12000","0.022","0.029","0.039","380","430" "TBA","750","3","21.2","18000","0.014","0.022","0.038","475","535" "All dimensions are nominal and subject to normal manufacturing tolerances"