"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Ground","Jacket Thickness","Approx. OD","Aluminum Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","No. x AWG","mils","inches","lbs./MFT","lbs./MFT" "TBA","8","7","3","0.134","35","1 x 8","60","0.563","61","160" "671383","6","7","3","0.169","30","1 x 8","60","0.663","90","220" "TBA","4","7","3","0.212","50","1 x 6","60","0.796","142","317" "675613","2","7","3","0.268","40","1 x 6","80","0.945","214","569" "675618","1","8","3","0.298","50","1 x 6","80","1.052","263","661" "588023","1","8","3","0.298","50","1 x 4","80","1.104","278","599" "675620","1/0","10","3","0.336","50","1 x 4","80","1.132","341","763" "675622","2/0","12","3","0.376","50","1 x 3","80","1.218","429","880" "675624","3/0","15","3","0.422","50","1 x 4","80","1.319","518","1001" "578218","4/0","3","3","0.474","50","1 x 2","80","1.432","667","1145" "673253","4/0","19","3","0.474","50","1 x 2","80","1.432","667","1140" "583386","250","22","3","0.520","60","1 x 2","80","1.577","776","1363" "675626","250","22","3","0.520","60","1 x 2","80","1.577","776","1366" "TBA","300","37","3","0.569","70","1 x 2","110","1.753","914","1615" "TBA","350","37","3","0.615","70","1 x 2","110","1.853","1056","1811" "678099","500","34","3","0.735","60","1 x 1","110","2.103","1506","2464" "599317","600","41","3","0.812","70","1 x 4/0","110","2.318","1914","2925" "673497","600","41","3","0.812","70","1 x 600","110","2.498","2283","3358" "677400","750","58","3","0.908","70","1 x 3/0","110","2.522","2300","3580" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "TBA","8","3","2.3","297","1.072","1.290","0.052","35","40","45" "671383","6","3","2.7","472","0.674","0.812","0.051","40","50","55" "TBA","4","3","3.2","751","0.424","0.510","0.048","55","65","75" "675613","2","3","3.8","1194","0.267","0.321","0.045","75","90","100" "675618","1","3","5.3","1506","0.211","0.254","0.046","85","100","115" "588023","1","3","5.5","1506","0.211","0.254","0.046","85","100","115" "675620","1/0","3","5.7","1900","0.168","0.201","0.044","100","120","135" "675622","2/0","3","6.1","2395","0.133","0.160","0.043","115","135","150" "675624","3/0","3","6.6","3020","0.105","0.126","0.042","130","155","175" "578218","4/0","3","7.2","3808","0.084","0.100","0.041","150","180","205" "673253","4/0","3","7.2","3808","0.084","0.100","0.041","150","180","205" "583386","250","3","7.9","4500","0.071","0.086","0.041","170","205","230" "675626","250","3","7.9","4500","0.071","0.086","0.041","170","205","230" "TBA","300","3","8.8","5400","0.059","0.071","0.041","195","230","260" "TBA","350","3","9.3","6300","0.050","0.062","0.040","210","250","280" "678099","500","3","12.6","9000","0.035","0.044","0.039","260","310","350" "599317","600","3","13.9","10800","0.029","0.037","0.039","285","340","385" "673497","600","3","15.0","10800","0.029","0.037","0.039","285","340","385" "677400","750","3","15.1","13500","0.024","0.031","0.038","320","385","435" "All dimensions are nominal and subject to normal manufacturing tolerances"