"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Ground","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","No. x AWG","mils","inches","lbs./MFT","lbs./MFT" "591981","8","7","3","0.141","45","1 x 10","60","0.647","186","307" "591983","6","7","3","0.177","45","1 x 8","60","0.724","297","441" "591985","4","7","3","0.225","45","1 x 8","60","0.853","441","634" "591987","2","7","3","0.282","45","1 x 6","80","0.978","702","930" "591989","1","19","3","0.322","55","1 x 6","80","1.162","864","1198" "591991","1/0","19","3","0.361","55","1 x 6","80","1.216","1069","1406" "591993","2/0","19","3","0.405","55","1 x 6","80","1.329","1326","1719" "591995","3/0","19","3","0.456","55","1 x 4","80","1.437","1699","2127" "591996","4/0","19","3","0.512","55","1 x 4","80","1.558","2109","2579" "591998","250","37","3","0.558","65","1 x 4","80","1.755","2469","3091" "592000","350","37","3","0.661","65","1 x 3","110","1.990","3438","4167" "674038","500","37","3","0.789","65","1 x 3/0","110","2.224","5201","5976" "592002","500","37","3","0.789","65","1 x 2","115","2.225","4884","5681" "TBA","750","61","3","0.968","80","1 x 1","110","2.658","7268","8547" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "591981","8","3","2.6","396","0.653","0.786","0.052","40","50","55" "591983","6","3","2.9","629","0.411","0.495","0.051","55","65","75" "591985","4","3","3.4","1001","0.258","0.310","0.048","70","85","95" "591987","2","3","3.9","1592","0.162","0.195","0.045","95","115","130" "591989","1","3","5.8","2008","0.128","0.154","0.046","110","130","145" "591991","1/0","3","6.1","2534","0.102","0.122","0.044","125","150","170" "591993","2/0","3","6.6","3194","0.081","0.097","0.043","145","175","195" "591995","3/0","3","7.2","4027","0.064","0.078","0.042","165","200","225" "591996","4/0","3","7.8","5078","0.051","0.062","0.041","195","230","260" "591998","250","3","8.8","6000","0.043","0.053","0.041","215","255","290" "592000","350","3","10.0","8400","0.031","0.039","0.040","260","310","350" "674038","500","3","13.3","12000","0.022","0.029","0.039","320","380","430" "592002","500","3","13.4","12000","0.022","0.029","0.039","320","380","430" "TBA","750","3","15.9","18000","0.014","0.022","0.038","400","475","535" "All dimensions are nominal and subject to normal manufacturing tolerances"