"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","mils","inches","lbs./MFT","lbs./MFT" "571253","12","19","0","0.091","45","15","0.210","20","36" "560057","10","19","1","0.125","55","25","0.265","32","58" "TBA","8","37","1","0.145","55","30","0.330","52","92" "167015","6","65","1","0.186","50","30","0.370","81","127" "167017","4","105","1","0.235","60","35","0.440","133","196" "167019","2","161","1","0.290","60","35","0.500","210","282" "167020","1","210","1","0.330","85","60","0.635","267","400" "167021","1/0","266","1","0.379","75","55","0.645","327","450" "167022","2/0","342","1","0.400","80","50","0.690","423","566" "167023","3/0","418","1","0.480","80","55","0.760","518","676" "167024","4/0","532","1","0.530","80","60","0.815","638","815" "167026","262.2","646","1","0.565","80","60","0.845","740","974" "167027","313.3","779","1","0.650","90","70","0.980","896","1139" "167029","373.7","931","1","0.701","95","70","1.040","1076","1343" "167030","444.4","1121","1","0.782","90","65","1.105","1378","1654" "167031","535.3","1330","1","0.843","105","75","1.212","1549","1889" "167032","646.4","1628","1","0.890","115","80","1.290","1898","2292" "167033","777.7","1924","1","0.966","120","90","1.405","2246","2727" "167035","1111","2745","1","1.168","115","95","1.640","3560","4161" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 75C","Allowable Ampacity At 90C","Allowable Ampacity In Air 75C","Allowable Ampacity In Air 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amp","Amp" "571253","12","0","0.8","52","1.774","2.301","0.054","25","30","35","40" "560057","10","1","1.1","83","1.081","1.302","0.050","35","40","50","55" "TBA","8","1","1.3","132","0.679","0.818","0.052","50","55","70","80" "167015","6","1","1.5","209","0.435","0.524","0.051","65","75","95","105" "167017","4","1","1.8","333","0.274","0.330","0.048","85","95","125","140" "167019","2","1","2.0","530","0.172","0.207","0.045","115","130","170","190" "167020","1","1","2.5","670","0.143","0.186","0.046","130","145","195","220" "167021","1/0","1","2.6","844","0.109","0.131","0.044","150","170","230","260" "167022","2/0","1","2.8","1064","0.087","0.104","0.043","175","195","265","300" "167023","3/0","1","3.0","1342","0.069","0.083","0.042","200","225","310","350" "167024","4/0","1","3.3","1692","0.055","0.067","0.041","230","260","360","405" "167026","262.2","1","3.4","3555","0.026","0.033","0.031","264","301","415","466" "167027","313.3","1","3.9","2506","0.039","0.048","0.031","298","332","460","518" "167029","373.7","1","5.2","2989","0.033","0.042","0.031","323","365","524","592" "167030","444.4","1","5.5","3555","0.026","0.040","0.029","358","405","578","652" "167031","535.3","1","6.1","4282","0.021","0.028","0.030","394","446","644","730" "167032","646.4","1","6.5","5171","0.018","0.025","0.030","439","496","720","812" "167033","777.7","1","7.0","6221","0.016","0.024","0.030","483","543","801","905" "167035","1111","1","8.2","8888","0.011","0.016","0.029","570","648","993","1119" "All dimensions are nominal and subject to normal manufacturing tolerances"